Modbus Client
TsgcModbusTCPClient and TsgcModbusRTUClient: Modbus TCP and Modbus RTU client for Delphi, C++Builder and .NET, with typed 32-bit values, retries, TLS and gateway support.
TsgcModbusTCPClient and TsgcModbusRTUClient: Modbus TCP and Modbus RTU client for Delphi, C++Builder and .NET, with typed 32-bit values, retries, TLS and gateway support.
Read and write the coils and registers of PLCs, energy meters and drives from Delphi, C++Builder and .NET, over TCP/IP or over an RS-232 or RS-485 serial line. The two clients have the same methods: TsgcModbusTCPClient connects to a Modbus TCP device or gateway, and TsgcModbusRTUClient is a Modbus RTU master on a serial line. The framing, timing and error handling of Modbus are done by the component, so your code only deals with addresses and values.
TsgcModbusTCPClient, TsgcModbusRTUClient| Standards & specs | Modbus Application Protocol Specification V1.1b3 · Modbus Messaging on TCP/IP Implementation Guide V1.0b · Modbus over Serial Line Specification V1.02 |
| Component classes | TsgcModbusTCPClient and TsgcModbusRTUClient (unit sgcModbus_Client; in Delphi add sgcIndustrial to the uses clause). In .NET the classes have the same names in the namespace esegece.sgcWebSockets. |
| Function codes | 01, 02, 03, 04, 05, 06, 15, 16, 22, 23 and 43/14. RTU only: 07 and 08. |
| Word orders | mwoABCD, mwoDCBA, mwoBADC, mwoCDAB |
| Default TCP port | 502 (CS_MODBUS_TCP_DEFAULT_PORT) |
| Exceptions | EsgcModbusException (exception reply), EsgcModbusTimeout (no answer), EsgcModbusError (any other problem) |
| Frameworks | VCL, FireMonkey, .NET |
| Platforms | TCP: every platform of sgcWebSockets. RTU: Windows, Linux and macOS |
The principal published properties used to configure and drive the component. Consult the online help for the full list.
UnitId | Unit id (slave address) of the device the requests go to. |
Timeout | Milliseconds each attempt waits for the response. |
Retries | Additional attempts after a timeout. |
WordOrder | Order of the two registers of a 32-bit value: ABCD, DCBA, BADC or CDAB. |
NotifyEvents | How the events are delivered. |
Active | TCP client: connects to or disconnects from the device. |
Host | TCP client: address of the device or gateway. |
Port | TCP client: TCP port, 502 by default. |
ConnectTimeout | TCP client: connection timeout in milliseconds. |
TLS / TLSOptions | TCP client: secure the connection with TLS. |
Proxy | TCP client: connect through a proxy. |
WatchDog | TCP client: reconnect automatically when the connection drops. |
SerialPort | RTU client: the open TsgcSerialPort used as transport. |
TurnaroundDelay | RTU client: pause after a broadcast write, in milliseconds. |
The principal public methods exposed by the component.
ReadCoils() | Function 01, reads coils. |
ReadDiscreteInputs() | Function 02, reads discrete inputs. |
ReadHoldingRegisters() | Function 03, reads holding registers. |
ReadInputRegisters() | Function 04, reads input registers. |
WriteSingleCoil() | Function 05, writes one coil. |
WriteSingleRegister() | Function 06, writes one holding register. |
WriteMultipleCoils() | Function 15, writes several coils. |
WriteMultipleRegisters() | Function 16, writes several holding registers. |
MaskWriteRegister() | Function 22, changes bits of a holding register with an AND and an OR mask. |
ReadWriteMultipleRegisters() | Function 23, writes and reads holding registers in one transaction. |
ReadDeviceIdentification() | Function 43/14, reads the identification objects of the device, with paging. |
ReadInt32() / WriteInt32() | Signed 32-bit value in two holding registers, in the order set by WordOrder. |
ReadUInt32() / WriteUInt32() | Unsigned 32-bit value in two holding registers. |
ReadFloat32() / WriteFloat32() | IEEE 754 single precision value in two holding registers. |
ReadInputInt32() / ReadInputUInt32() / ReadInputFloat32() | The same typed reads from input registers. |
ReadString() / WriteString() | Text stored in holding registers. |
ReadExceptionStatus() | RTU client, function 07. |
Diagnostics() | RTU client, function 08. |
The published events of the component.
OnConnect | TCP client: the connection is established. |
OnDisconnect | TCP client: the connection is closed. |
OnError | TCP client: an error happened on the connection. |
Set Host and UnitId, set Active to True and call the methods. The snippet that follows shows the typical Connect, read and write over Modbus TCP flow, the same compiled sample as the component page.
uses sgcIndustrial; procedure TForm1.ConnectClient; begin FClient := TsgcModbusTCPClient.Create(Self); FClient.Host := '192.168.1.50'; FClient.Port := 502; FClient.UnitId := 1; FClient.Timeout := 1000; FClient.Retries := 2; FClient.OnConnect := OnModbusConnect; FClient.OnError := OnModbusError; FClient.Active := True; end; procedure TForm1.OnModbusConnect(Sender: TObject); begin Memo1.Lines.Add('Connected'); end; procedure TForm1.ReadValues; var vRegisters: TsgcModbusRegisters; vTemperature: Single; begin try vRegisters := FClient.ReadHoldingRegisters(0, 10); FClient.WriteSingleCoil(10, True); // 32-bit float stored low word first by many PLCs FClient.WordOrder := mwoCDAB; vTemperature := FClient.ReadFloat32(300); Memo1.Lines.Add(Format('HR0 = %d, temperature = %.1f', [vRegisters[0], vTemperature])); except on E: EsgcModbusException do Memo1.Lines.Add(Format('Device exception %d', [E.ExceptionCode])); on E: EsgcModbusTimeout do Memo1.Lines.Add('No response'); end; end; procedure TForm1.OnModbusError(Sender: TObject; const aError: string); begin Memo1.Lines.Add('Error: ' + aError); end;
#include "sgcIndustrial.hpp" void __fastcall TForm1::ConnectClient() { FClient = new TsgcModbusTCPClient(this); FClient->Host = "192.168.1.50"; // Port is 502 by default FClient->UnitId = 1; FClient->Timeout = 1000; FClient->Retries = 2; FClient->OnConnect = OnModbusConnect; FClient->OnError = OnModbusError; FClient->Active = true; } void __fastcall TForm1::OnModbusConnect(TObject *Sender) { Memo1->Lines->Add("Connected"); } void __fastcall TForm1::ReadValues() { try { TsgcModbusRegisters vRegisters = FClient->ReadHoldingRegisters(0, 10); FClient->WriteSingleCoil(10, true); // 32-bit float stored low word first by many PLCs FClient->WordOrder = mwoCDAB; float vTemperature = FClient->ReadFloat32(300); Memo1->Lines->Add("HR0 = " + IntToStr(vRegisters[0]) + ", temperature = " + FloatToStrF(vTemperature, ffFixed, 7, 1)); } catch (EsgcModbusException &E) { Memo1->Lines->Add("Device exception " + IntToStr(E.ExceptionCode)); } catch (EsgcModbusTimeout &E) { Memo1->Lines->Add("No response"); } } void __fastcall TForm1::OnModbusError(TObject *Sender, const String aError) { Memo1->Lines->Add("Error: " + aError); }
using System; using esegece.sgcWebSockets; class PlcClient { TsgcModbusTCPClient FClient = new TsgcModbusTCPClient(); public void ConnectClient() { FClient.Host = "192.168.1.50"; FClient.Port = 502; FClient.UnitId = 1; FClient.Timeout = 1000; FClient.Retries = 2; FClient.OnConnect += OnModbusConnect; FClient.OnError += OnModbusError; FClient.Active = true; } void OnModbusConnect(object Sender, EventArgs e) { Console.WriteLine("Connected"); } public void ReadValues() { try { ushort[] vRegisters = FClient.ReadHoldingRegisters(0, 10); FClient.WriteSingleCoil(10, true); // 32-bit float stored low word first by many PLCs FClient.WordOrder = TsgcModbusWordOrder.mwoCDAB; float vTemperature = FClient.ReadFloat32(300); Console.WriteLine($"HR0 = {vRegisters[0]}, temperature = {vTemperature:F1}"); } catch (EsgcModbusException E) { Console.WriteLine("Device exception " + E.ExceptionCode); } catch (EsgcModbusTimeout) { Console.WriteLine("No response"); } } void OnModbusError(object Sender, string aError) { Console.WriteLine("Error: " + aError); } }
The following scenarios use the same compiled samples as the component page. Each shows the configuration and method calls needed to drive the component through a specific real-world flow.
Open a TsgcSerialPort, link it with SerialPort and set the slave address in UnitId. The client builds the RTU frame with its CRC16 and waits for the slave.
procedure TForm1.ReadSlave; var vRegisters: TsgcModbusRegisters; begin FPort := TsgcSerialPort.Create(Self); FPort.Port := 'COM4'; FPort.BaudRate := 19200; FPort.Parity := spEven; FPort.Open; FRTU := TsgcModbusRTUClient.Create(Self); FRTU.SerialPort := FPort; FRTU.UnitId := 17; FRTU.Timeout := 500; FRTU.Retries := 2; vRegisters := FRTU.ReadHoldingRegisters(107, 3); Memo1.Lines.Add(Format('Register 107 = %d', [vRegisters[0]])); // unit id 0 = broadcast: every slave executes the write, none answers FRTU.WriteSingleRegister(0, 1, 100); end;
void __fastcall TForm1::ReadSlave() { FPort = new TsgcSerialPort(this); FPort->Port = "COM4"; FPort->BaudRate = 19200; FPort->Parity = spEven; FPort->Open(); FRTU = new TsgcModbusRTUClient(this); FRTU->SerialPort = FPort; FRTU->UnitId = 17; FRTU->Timeout = 500; FRTU->Retries = 2; TsgcModbusRegisters vRegisters = FRTU->ReadHoldingRegisters(107, 3); Memo1->Lines->Add("Register 107 = " + IntToStr(vRegisters[0])); // unit id 0 = broadcast: every slave executes the write, none answers FRTU->WriteSingleRegister(0, 1, 100); }
using System; using esegece.sgcWebSockets; class RtuMaster { TsgcSerialPort FPort = new TsgcSerialPort(); TsgcModbusRTUClient FRTU = new TsgcModbusRTUClient(); public void ReadSlave() { FPort.Port = "COM4"; FPort.BaudRate = 19200; FPort.Parity = TsgcSerialParity.spEven; FPort.Open(); FRTU.SerialPort = FPort; FRTU.UnitId = 17; FRTU.Timeout = 500; FRTU.Retries = 2; ushort[] vRegisters = FRTU.ReadHoldingRegisters(107, 3); Console.WriteLine("Register 107 = " + vRegisters[0]); // unit id 0 = broadcast: every slave executes the write, none answers FRTU.WriteSingleRegister(0, 1, 100); } }
Every external claim links back to a primary source. The online-help references decode the canonical deep-link the company maintains for this component.